Advantage of Electric Spray Foam Pump
Electric spray Foam
Pump(KEXON) systems are reliable, and under the right conditions and with
proper maintenance contractors can achieve good results with these systems for
up to 15 years or longer. In fact, they are as reliable as the electric motor
pumps they are built on, and some electric motor pump technology has been used
for more than 25 years.
These systems employ primary heaters that heat the chemical to the operating temperature. High quality systems also feature heated hoses to maintain the temperature set point and ensure that good quality foam is applied.
The foam and polyurea chemicals used with spray foam systems must be heated to a range of 110?F to 180?F. Electric spray foam systems typically have large electric primary heaters to heat the chemicals to the desired temperature set point. ?In theory, the hoses could simply be insulated to maintain chemical temperature set points, but insulation is not enough when a contractor starts up in the morning or during an extended shutdown during the day.
Heated hoses raise the chemical temperatures in the hose to operating levels at start up and maintain the temperature set point throughout the day.While maintaining the temperature of the chemicals is key, heated hoses should not be used as a way to boost chemical temperatures above the temperature set point of the primary heaters. In addition, electrical power in 200-240 or 350-415 voltage is required for the proportioning pump, primary heaters and heated hose. Compressed air also is required for the applicator.
Click Foam Pump Suppliers to learn about more information
These systems employ primary heaters that heat the chemical to the operating temperature. High quality systems also feature heated hoses to maintain the temperature set point and ensure that good quality foam is applied.
The foam and polyurea chemicals used with spray foam systems must be heated to a range of 110?F to 180?F. Electric spray foam systems typically have large electric primary heaters to heat the chemicals to the desired temperature set point. ?In theory, the hoses could simply be insulated to maintain chemical temperature set points, but insulation is not enough when a contractor starts up in the morning or during an extended shutdown during the day.
Heated hoses raise the chemical temperatures in the hose to operating levels at start up and maintain the temperature set point throughout the day.While maintaining the temperature of the chemicals is key, heated hoses should not be used as a way to boost chemical temperatures above the temperature set point of the primary heaters. In addition, electrical power in 200-240 or 350-415 voltage is required for the proportioning pump, primary heaters and heated hose. Compressed air also is required for the applicator.
Click Foam Pump Suppliers to learn about more information